Power
Solar
Buy panels before December 4, 2026. From that date imported solar panels carry a new 15% tariff and a minimum import price, and analysts expect prices to rise. Until December 3 a Commerce Department rule stops importers from bringing in more panels than usual ahead of the tariff. The rule limits importers, not you.
- View on Amazon
A single rigid 200 W solar panel for a fixed mount.
Tech specs
Maximum power 200 W Working voltage (Vmp) 19.02 V Working current (Imp) 10.5 A Open-circuit voltage (Voc) 22.4 V Short-circuit current (Isc) 11.04 A Maximum series fuse 20 A System type 12 V Size 46.3 × 30.1 × 1.2 in Weight 20.2 lb Figures from the Amazon listing.
Suggested setups
Into Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 6 in seriesany 1 to 6 in series works 148 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 6 in seriesany 1 to 6 in series works 153 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 6 in seriesany 1 to 6 in series works 159 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 6 in seriesany 1 to 6 in series works 163 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 5 in seriesany 1 to 5 in series works 140 V limit 165 V 11 A limit 17 A 1,000 W 2,000 W 10 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 19 in seriesany 7 to 19 in series works 468 V limit 480 V 11 A limit 25 A 3,800 W 7,600 W 38 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 18 in seriesany 7 to 18 in series works 460 V limit 480 V 11 A limit 25 A 3,600 W 7,200 W 36 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 18 in seriesany 7 to 18 in series works 476 V limit 480 V 11 A limit 25 A 3,600 W 7,200 W 36 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 17 in seriesany 7 to 17 in series works 461 V limit 480 V 11 A limit 25 A 3,400 W 6,800 W 34 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 17 in seriesany 7 to 17 in series works 476 V limit 480 V 11 A limit 25 A 3,400 W 6,800 W 34 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 4 in seriesany 2 to 4 in series works 99 V limit 100 V 11 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededOne string can't overload itself. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 51 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 53 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 54 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 56 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
- View on Amazon
Four rigid 200 W solar panels (800 W in all) for a fixed mount on a roof, rack or the ground.
Tech specs
Maximum power 200 W Working voltage (Vmp) 31.03 V Working current (Imp) 6.46 A Open-circuit voltage (Voc) 37.44 V Short-circuit current (Isc) 6.85 A Maximum series fuse 15 A Panels in the pack 4 (figures above are per panel) System type 24 V Size 49.7 × 30.1 × 1.2 in Weight 93.6 lb for the four Figures from the Amazon listing.
Suggested setups
Into Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 strings of 4 in series, joined with a 2-to-1 Y connector 165 V limit 165 V 13.7 A limit 17 A 1,600 W 3,200 W 16 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 strings of 3 in series, joined with a 2-to-1 Y connector 128 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 strings of 3 in series, joined with a 2-to-1 Y connector 133 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 strings of 3 in series, joined with a 2-to-1 Y connector 136 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 strings of 3 in series, joined with a 2-to-1 Y connector 140 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 2 strings of 10 in series, joined with a 2-to-1 Y connector 412 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 2 strings of 10 in series, joined with a 2-to-1 Y connector 427 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 2 strings of 10 in series, joined with a 2-to-1 Y connector 442 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 2 strings of 10 in series, joined with a 2-to-1 Y connector 453 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 2 strings of 10 in series, joined with a 2-to-1 Y connector 468 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 82 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 85 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 88 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 91 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Victron SmartSolar MPPT 100/50 charge controller 2 strings of 2 in series, joined with a 2-to-1 Y connector 94 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
- View on Amazon
A portable 450 W solar panel that you set out in the sun and plug into a power station or charge controller.
Explanation
- If you're not an electrician, portable panels are much harder to get wrong.
- Buy all the panels you'll need at once, of one model: mismatched panels wired together drag each other down. Check your power station's solar input limits first.
Tech specs
Maximum power 450 W Working voltage (Vmp) 38.3 V Working current (Imp) 11.7 A Open-circuit voltage (Voc) 45.9 V Short-circuit current (Isc) 12.4 A Cells Monocrystalline N-type Folded size 30.4 × 34.6 × 3.5 in Unfolded size 121.9 × 34.6 × 0.8 in Weight 29.5 lb Operating temperature −4°F to 140°F Figures from the maker's spec sheet; it gives no maximum series fuse.
Suggested setups
Into Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 3 in seriesany 1 to 3 in series works 151 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 3 in seriesany 1 to 3 in series works 157 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 3 in seriesany 1 to 3 in series works 162 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 in seriesany 1 to 2 in series works 111 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 in seriesany 1 to 2 in series works 115 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 9 in seriesany 4 to 9 in series works 454 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 9 in seriesany 4 to 9 in series works 471 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 8 in seriesany 4 to 8 in series works 433 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 8 in seriesany 4 to 8 in series works 444 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 8 in seriesany 4 to 8 in series works 459 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 50 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 52 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 54 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 56 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 57 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
- View on Amazon
A lighter, bifacial version of the ZOUPW 450 W portable panel: it also catches light reflected onto its back.
Explanation
Largely the same as the ZOUPW 450W above, but about 30% lighter and more resilient to shade. In general it would be more reliable if your solar input capacity is limited, as on portable power stations. Whether that's worth the higher price is up to you.
Tech specs
Maximum power 450 W Working voltage (Vmp) 40 V Working current (Imp) 11.7 A Open-circuit voltage (Voc) 46 V Short-circuit current (Isc) 12.4 A Cells Monocrystalline N-type, bifacial Folded size 30.4 × 34.6 × 3.5 in Unfolded size 121.9 × 34.6 × 0.9 in Weight 20.9 lb Operating temperature −4°F to 140°F Figures from the maker's spec sheet; it gives no maximum series fuse.
Suggested setups
Into Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 3 in seriesany 1 to 3 in series works 152 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 3 in seriesany 1 to 3 in series works 157 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 3 in seriesany 1 to 3 in series works 163 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 in seriesany 1 to 2 in series works 111 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh) 2 in seriesany 1 to 2 in series works 115 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 9 in seriesany 3 to 9 in series works 455 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 9 in seriesany 3 to 9 in series works 472 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 8 in seriesany 3 to 8 in series works 434 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 8 in seriesany 3 to 8 in series works 445 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. EG4 6000XP off-grid inverter (6,000 W, 120/240 V) 8 in seriesany 3 to 8 in series works 460 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 51 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 52 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 54 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 56 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Victron SmartSolar MPPT 100/50 charge controller 2 in parallel, joined with a 2-to-1 Y connector 58 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
Connection
String fuses are needed only where three or more strings of panels join in parallel on one solar input, as in large arrays wired through a combiner box. None of the setups on this page need them; each panel's Suggested setups says when one does. Separately, an inverter wired to its own battery, like the EG4 or the Victron 12/1200, needs a fuse or breaker on the battery cable; all-in-one power stations have this built in.
- View on Amazon
A 60 A DC breaker in a weatherproof box that protects the charge controller's battery cable and switches it off.
Explanation
- Goes on the battery cable of a Victron SmartSolar 100/50 charge controller, which Victron says needs a 55 to 70 A fuse or breaker there.
- Run the controller's positive through one pole and its negative through the other, so switching it off disconnects the controller completely. It isn't polarized, so either side can face the battery.
Tech specs
Rating 60 A, 2 poles, 12 to 400 V DC, C trip curve Breaking capacity 4 kA (the listing also gives 6 kA) Cable entry IP68 glands for 4 to 9 mm cable (11 to 5 AWG); crimp ferrules included Figures from the Amazon listing.
- View on Amazon
Y connectors that join the cables from two panels into one line.
Tech specs
Rated current 30 A Rated voltage 1,000 V DC Cable 14 to 10 AWG Pairs 4 (each: one 1-male-to-2-female, one 1-female-to-2-male) Weatherproofing IP68 Figures from the Amazon listing.
- View on Amazon
Outdoor-rated solar cable for running power from the panels to a charge controller, inverter or power station.
Tech specs
Gauge 10 AWG (6 mm²) Conductor Tinned copper, 84 strands Voltage rating 1,800 V DC Standards TÜV, IEC 62930 Figures from the Amazon listing.
Batteries
- View on Amazon
An all-in-one battery backup: battery, 120/240 V inverter and solar charging in one unit, 7,680 Wh in this kit per the listing.
Explanation
If you'd rather skip the extremely complicated job of building a battery backup system out of raw components, get this all-in-one kit.
Tech specs
Solar inputs 2 per F3800 Plus unit Input voltage 11–165 V; never above 165 V open-circuit Current per input 17 A Power per input 1,600 W Battery 3,840 Wh LiFePO4 per unit; 7,680 Wh for this kit per the listing Expansion Up to 26.9 kWh per unit with 6 expansion batteries AC output 6,000 W, 120 V and 240 V, per unit Solar 3,200 W per unit AC charging 1,800 W per unit UPS switchover 20 ms Idle draw About 30 to 40 W with the AC outlets on and nothing plugged in, so 0.7 to 1 kWh a day (PCMag, 2026). Before Anker's mid-2025 firmware update reviewers saw 50 to 70 W; Anker says the update halved it Cycle life 3,000+ cycles to 80% Operating temperature Discharges −4 to 104°F, charges 32 to 104°F Weight 136.7 lb per unit; 27.6 × 15.3 × 15.6 in Figures from the Amazon listing and Anker's F3800 Plus page; idle draw from PCMag's 2026 review and How-To Geek (Anker publishes no figure).
Suggested setups
Panel Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse HQST 200W N-Type solar panel 6 in seriesany 1 to 6 in series works 148 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 6 in seriesany 1 to 6 in series works 153 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 6 in seriesany 1 to 6 in series works 159 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 6 in seriesany 1 to 6 in series works 163 V limit 165 V 11 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 5 in seriesany 1 to 5 in series works 140 V limit 165 V 11 A limit 17 A 1,000 W 2,000 W 10 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 4 in series, joined with a 2-to-1 Y connector 165 V limit 165 V 13.7 A limit 17 A 1,600 W 3,200 W 16 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 3 in series, joined with a 2-to-1 Y connector 128 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 3 in series, joined with a 2-to-1 Y connector 133 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 3 in series, joined with a 2-to-1 Y connector 136 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 3 in series, joined with a 2-to-1 Y connector 140 V limit 165 V 13.7 A limit 17 A 1,200 W 2,400 W 12 panels, 2 inputs per F3800 Plus unit Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. ZOUPW 450W portable solar panel 3 in seriesany 1 to 3 in series works 151 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 3 in seriesany 1 to 3 in series works 157 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 3 in seriesany 1 to 3 in series works 162 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 2 in seriesany 1 to 2 in series works 111 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 2 in seriesany 1 to 2 in series works 115 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 3 in seriesany 1 to 3 in series works 152 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 3 in seriesany 1 to 3 in series works 157 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 3 in seriesany 1 to 3 in series works 163 V limit 165 V 12.4 A limit 17 A 1,350 W 2,700 W 6 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in seriesany 1 to 2 in series works 111 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in seriesany 1 to 2 in series works 115 V limit 165 V 12.4 A limit 17 A 900 W 1,800 W 4 panels, 2 inputs per F3800 Plus unit Not neededOne string can't overload itself. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
- View on Amazon
A 12 V lithium (LiFePO4) battery that stores 3,584 Wh: the heart of the small battery station.
Explanation
- With the Victron inverter and charge controller, this makes a small, cheap battery station that keeps a fridge or freezer running through an outage.
- To see how long it lasts, find your fridge's yearly kWh on its yellow EnergyGuide label, divide by 365 for a day's use, and add about a quarter of a kWh a day for the inverter.
- Keep it indoors: it stops charging in the cold to protect itself.
Tech specs
Battery 280 Ah at 12.8 V, 3,584 Wh LiFePO4 BMS 200 A, stops charging at low temperatures Monitoring Bluetooth app Case Metal, with mounting feet; no battery box needed Charge settings 14.6 V absorption; float off, or 13.8 V if it can't be turned off; no equalization Warranty 3 years Safety switch Cuts the discharge circuit Idle draw Not published (BMS and Bluetooth) Figures from the Amazon listing.
- View on Amazon
A 48 V lithium (LiFePO4) server-rack battery that stores 5,120 Wh, for a 48 V inverter such as the EG4.
Tech specs
Battery 100 Ah at 51.2 V, 5,120 Wh LiFePO4 Expansion Up to 32 in parallel (163.8 kWh) Inverter communication CAN and RS485 (closed loop) Monitoring Bluetooth and Wi-Fi app Certifications UL9540, UL9540A, UL1973, CEC listed Included Parallel, communication and grounding cables, terminal covers, screws Size and weight 22.09 × 19.02 × 5.63 in, 103 lb; fits a server rack Warranty 10 years Idle draw Not published (BMS, Bluetooth and Wi-Fi) Figures from the Amazon listing.
- View on Amazon
Keeps 12 V batteries wired in series (to make 24, 36 or 48 V) all at the same charge.
Explanation
That way none of them is overcharged or run too low.
Tech specs
Bank 12 V batteries wired in series to 24, 36 or 48 V Balancing current Up to 10 A Balances until Batteries are within 10 mV of each other Battery types LiFePO4, lithium-ion, lead-acid (AGM, gel, flooded) Protection Reverse polarity, high temperature Idle draw Under 5 mA once the batteries are within 10 mV Figures from the Amazon listing.
Inverters and charge controllers
- View at Signature Solar
A 6,000 W off-grid inverter that charges a battery bank from solar and turns its power into 120/240 V household power.
Explanation
- Shove as much voltage into it as you can: wire panels in long series strings, up to its 480 V limit. Suggested setups works out how many of each panel.
- It needs a separate 48 V battery bank.
Tech specs
Solar inputs 2 Input voltage 100–480 V; never above 480 V open-circuit Full-power voltage 120–385 V Current per input 17 A usable; short-circuit up to 25 A Power per input 4,000 W AC output 6,000 W, 120/240 V split phase Surge 12 kW for about 3.5 seconds Battery 48 V, not included; over 200 Ah recommended Battery current Charges at up to 125 A, discharges at up to 140 A Solar 8,000 W used (4,000 W per input); start-up at 100 V Generator or grid input Up to 9,000 W Expansion Up to 16 units in parallel Idle draw About 50 W on battery, under 50 W on grid, under 30 W running from solar (EG4's figures, measured with a steady 300 V solar input); about 1.2 kWh a day on battery Figures from EG4's 6000XP spec sheet (version 1.2.1) and Signature Solar's product page.
Suggested setups
Panel Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse HQST 200W N-Type solar panel 19 in seriesany 7 to 19 in series works 468 V limit 480 V 11 A limit 25 A 3,800 W 7,600 W 38 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 18 in seriesany 7 to 18 in series works 460 V limit 480 V 11 A limit 25 A 3,600 W 7,200 W 36 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 18 in seriesany 7 to 18 in series works 476 V limit 480 V 11 A limit 25 A 3,600 W 7,200 W 36 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 17 in seriesany 7 to 17 in series works 461 V limit 480 V 11 A limit 25 A 3,400 W 6,800 W 34 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 17 in seriesany 7 to 17 in series works 476 V limit 480 V 11 A limit 25 A 3,400 W 6,800 W 34 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 10 in series, joined with a 2-to-1 Y connector 412 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 10 in series, joined with a 2-to-1 Y connector 427 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 10 in series, joined with a 2-to-1 Y connector 442 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 10 in series, joined with a 2-to-1 Y connector 453 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 10 in series, joined with a 2-to-1 Y connector 468 V limit 480 V 13.7 A limit 25 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. ZOUPW 450W portable solar panel 9 in seriesany 4 to 9 in series works 454 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 9 in seriesany 4 to 9 in series works 471 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 8 in seriesany 4 to 8 in series works 433 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 8 in seriesany 4 to 8 in series works 444 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 8 in seriesany 4 to 8 in series works 459 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 9 in seriesany 3 to 9 in series works 455 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 9 in seriesany 3 to 9 in series works 472 V limit 480 V 12.4 A limit 25 A 4,000 W 8,000 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 8 in seriesany 3 to 8 in series works 434 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 8 in seriesany 3 to 8 in series works 445 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 8 in seriesany 3 to 8 in series works 460 V limit 480 V 12.4 A limit 25 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
- View on Amazon
An inverter that turns a 12 V battery's power into 120 V household power, up to 1,000 W, while idling at only about 10 W.
Explanation
- A fridge's compressor runs only part of the time, but an inverter draws power around the clock, so its idle draw matters as much as its size. Its 2,200 W peak starts a fridge or freezer compressor.
- It runs 1,000 W continuously: enough for a fridge or freezer and small loads, not heaters or microwaves.
- It runs from a 12 V battery like the ECO-WORTHY, with the Go Power Class T fuse on its battery cable.
Tech specs
AC output 1,200 VA: 1,000 W continuous at 77°F, 850 W at 104°F; 120 V, one NEMA 5-15R GFCI outlet Peak 2,200 W Idle draw 10 W (11 W in Victron's 2026 120 V manual), about 0.25 kWh a day; 1 W in ECO mode Battery 12 V (9.2 to 17 V) Figures from Victron's Phoenix Inverter VE.Direct 250VA to 1200VA datasheet (the listing's bullet points give the smaller 800 VA model's figures); the 11 W from Victron's Inverter VE.Direct 120V manual (2026).
- View on Amazon
A solar charge controller: it charges a 12 V battery like the ECO-WORTHY from solar panels.
Explanation
- It takes up to 100 V, so panels go in short strings; on a 12 V battery it delivers up to 700 W, and panels beyond that are simply capped. Suggested setups works out how many of each panel.
- In its app, choose the LiFePO4 battery setting.
Tech specs
Solar inputs 1 Input voltage 20–100 V; never above 100 V open-circuit Current per input 60 A usable; short-circuit up to 60 A Power per input 700 W Battery 12 or 24 V, detected automatically Charge current 50 A Solar 700 W at 12 V, 1,400 W at 24 V; more panels are capped Solar input Up to 100 V open circuit and 60 A short circuit; starts once panels reach battery voltage plus 5 V Idle draw 30 mA at 12 V (about 0.4 W) Operating temperature −22 to 140°F; full output up to 104°F Figures from Victron's SmartSolar MPPT 100/30 and 100/50 datasheet.
Suggested setups
Panel Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse HQST 200W N-Type solar panel 4 in seriesany 2 to 4 in series works 99 V limit 100 V 11 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 2 strings of 2 in series, joined with a 2-to-1 Y connector 51 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. HQST 200W N-Type solar panel 2 strings of 2 in series, joined with a 2-to-1 Y connector 53 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. HQST 200W N-Type solar panel 2 strings of 2 in series, joined with a 2-to-1 Y connector 54 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. HQST 200W N-Type solar panel 2 strings of 2 in series, joined with a 2-to-1 Y connector 56 V limit 100 V 22.1 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 2 in series, joined with a 2-to-1 Y connector 82 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 2 in series, joined with a 2-to-1 Y connector 85 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 2 in series, joined with a 2-to-1 Y connector 88 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 2 in series, joined with a 2-to-1 Y connector 91 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 2 strings of 2 in series, joined with a 2-to-1 Y connector 94 V limit 100 V 13.7 A limit 60 A 700 W 700 W 4 panels, 1 input Not neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A. ZOUPW 450W portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 50 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 52 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 54 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 56 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 57 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 51 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 52 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 54 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 56 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 2 in parallel, joined with a 2-to-1 Y connector 58 V limit 100 V 24.8 A limit 60 A 700 W 700 W 2 panels, 1 input Not neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
Accessories
- View on Amazon
A surge protector for the solar lines of a power station or portable setup: it sends surges from nearby lightning to ground.
Explanation
- Lightning doesn't have to hit your panels to fry your charge controller or power station: a strike nearby induces a surge in the long wires from the panels, and this sends it to ground. It won't save anything from a direct hit.
- This 300 V version is for portable and power station setups; for inverter setups like the EG4, whose panel strings run up to 480 V, get the 600 V version below.
- You need one for each solar line going into your charge controller or power station, mounted right next to it, plus a second one at the panel end if that wire run is longer than about 30 feet.
- It only works wired with short, straight leads to a proper ground rod.
- Panels set out on the ground beside a power station on a short cable don't need one.
- Its blue lights go out at night; if they're out while the sun is up, replace it.
Tech specs
System voltage Up to 300 V DC Status lights Blue when voltage is present; off at night is normal Enclosure Type 4X, outdoor Size and weight 4.4 × 3.8 × 3.5 in, 1 lb Warranty 5 years Figures from the Amazon listing and MidNite's installation manual.
- View on Amazon
The same surge protector in a 600 V version, for inverter setups like the EG4.
Explanation
The EG4's panel strings run up to 480 V, too high for the 300 V version. Everything in the 300 V version's explanation applies: one for each solar input at the inverter, plus one at the panel end of runs longer than about 30 feet, wired with short, straight leads to a proper ground rod.
Tech specs
System voltage Up to 600 V DC Status lights Lit when voltage is present between DC+ and DC−; off at night is normal Weight 13.4 oz Figures from the Amazon listing and MidNite's installation manual.
- View on Amazon
A weatherproof on/off switch that disconnects two solar panel lines from whatever they feed.
Tech specs
Poles 4: two lines in and two out Rated voltage 1,500 V DC Rated current 32 A per pole Connectors 4 MC4 Enclosure IP66 Figures from the Amazon listing.
- View on Amazon
A cable that connects a Victron Phoenix inverter to a computer, to change its settings.
Explanation
The Victron Phoenix inverters have no Bluetooth. This cable connects one to a computer running Victron's free VictronConnect app, to change settings such as raising the low-battery shutdown.
Tech specs
Use Connects a VE.Direct port (the Phoenix inverter, the SmartSolar controller) to a computer's USB port for VictronConnect, or adds VE.Direct devices to a Victron GX device Part number ASS030530010 Warranty 5 years Figures from the Amazon listing.